Ez Io Needle Selection The EZ-IO® Catheter is marked with a black line 5 mm proximal to the hub. Covers indications, contraindications, insertion sites, equipment, technique and tips for securing the port. Both mechanical, drill-based insertion and manual . EZ-IO® NEEdlE SETS: dEScRIPTION Comprised of Catheter with Luer-lock connection, Stylet, Safety Cap. 4911 e non-collapsible vein. • Color-coded needle system enables quick selection and post-insertion identification. Always use clinical judgment to determine selection of the appropriate needle based on the patient's weight, the bone anatomy, and the tissue depth EZ-IO Needle selection (based on weight of patient) Pink 15mm (3-39kg) Blue 25mm (40kg and above) Yellow 45mm (excessive tissue or humerus) Procedure EZ IO Infant Child Needle Selection and Insertion Technique Animation Video Paramedic Rahul 140 subscribers Subscribed This intraosseous (IO) access guide provides a step-by-step approach to gaining intraosseous access in an OSCE setting. This guide will Site Identification & Selection Intraosseous (IO) site selection depends on patient age, size, anatomy, presenting condition; as well as ability to locate anatomical landmarks, and clinical judgment and Insertion Sites The Arrow EZ-IO Intraosseous Vascular Access System from Teleflex provides intraosseous access when intravenous access is difficult or impossible to obtain in emergent, urgent Proven,1 Fast,2* Effective3 In any situation where intravenous access is difficult to obtain in emergent, urgent, or medically necessary cases, the Arrow® EZ-IO® Intraosseous Vascular Access System Attach EZ-IO® Needle Set to EZ-IO® Power Driver and remove Safety Cap from Cannula. 680. Refer to EZ-IO Large Adult Needle - 45mm The Arrow® EZ-IO® Intraosseous Vascular Access System creates a stable port into the intraosseous space to access the Intraosseous Access Arrow ® EZ-IO ® Instructional Literature Proximal Humerus Data Sheet EZ-IO ® Pocket Guide EZ-IO ® Care, Maintenance and Removal What gauge is an IO needle? Learn the standard gauges, lengths, and color-coded sizes for intraosseous access in emergency situations for both adult and pediatric patients. more For proximal and distal tibia insertion the angle is 90-degrees to bone. This video reviews steps to correctly identify and insert in the Insertion Insert EZ IO needle into selected site: press needle perpendicular to the bone surface until needle tip touches bone Confirm that at least one black line is visible, otherwise the needle is too EZ-IO® NEEdlE SETS: dEScRIPTION Comprised of Catheter with Luer-lock connection, Stylet, Safety Cap. • The 5-mm mark, closest black line to the hub, must be visible above skin for needle set length confirmation. Refer to Arrow® EZ-IO® Infant Child Needle Selection and Insertion Technique Animation Video vidacare 2. Sterile, non-pyrogenic, in Arrow ® EZ-IO ® Needle Set The Arrow ® EZ-IO ® Needle Set is for vascular access anytime in which vascular access is difficult to obtain in emergent, The Arrow® EZ-IO® Needle Set is Sterile, Single Use: Do not reuse, reprocess, or resterilize. This guide explains IO needle sizes by color, length, and age group The Arrow EZ-IO Needle Set is Sterile, Single Use: Do not reuse, reprocess or re-sterilize. This can be performed by senior nursing staff who are familiar with the procedure. The 25mm needle set is Prior to drilling, with the EZ-IO® Needle Set inserted through the soft tissue and the needle tip touching bone, adequate needle length is determined by the ability to see the 5 mm black line above the skin. Sterile, non-pyrogenic, in Appropriate needle selection and insertion for an infant/child when using Arrow ® EZ-IO ® Intraosseous Vascular Access Arrow ® EZ-IO ® Needle+Stabilizer Kit - 25 mm The Arrow ® EZ-IO ® Needle Set is for vascular access anytime in which vascular access is difficult to obtain in ctions as a large non-collapsible vein. Reuse of device creates a potential risk of serious injury and/or Arrow EZ-IO Manual Needle Set The Arrow EZ-IO Manual Needle Set is designed to provide controlled vascular access via the intraosseous (IO) route to patients SET SELECTION Select EZ-IO® Needle Set based on patient weight, anatomy, and clinical judgment. Prior to drilling, with the Arrow® EZ-IO® Infant Child Needle Selection and Insertion Technique Animation Video SPEAR - Simplified Pneumothorax Emergency Air Release Hospital PPE - Infection Control: Donning and Doffing Live provider/adult patient scenario utilizing the Arrow® EZ-IO® Intraosseous Vascular Access System in the proximal tibia. EZ-IO Power Driver LED blinks red when the trigger is activated and Driver has only 10% of battery life remaining. IMPORTANT: Only handle EZ-IO® Needle Set by the plastic Hub. The ARROW® EZ-IO® Needle Set has a uniquely designed needle tip that drills a hole in the bone the same size as the needle, minimizing risk of EZ-IO Power Driver LED blinks red when the trigger is activated and Driver has only 10% of battery life remaining. Reuse of device creates a potential risk of serious injury and/or Site Selection (for EZ-IO system) Proximal Tibia- 2 finger breadths below tibial tuberosity (1-3 cm) on medial, flat aspect of tibia Distal Tibia- medial surface at junction of medial malleolus and shaft of BD ® Intraosseous Needles are the only IO needles that feature an integrated passive needle tip safety designed to protect against Arrow® EZ-IO® Needle + Stabilizer Kit (To be used with the Arrow® EZ-IO® Intraosseous Vascular Access System) The EZ-IO® enables safe, simple, and Safe,1 Fast,2,3* Effective4 In any situation where intravenous access is difficult or impossible to obtain in emergent, urgent, or medically necessary cases the Arrow EZ-IO Intraosseous Vascular Access Needle Selection Select EZ-IO® Needle Set based on patient weight (kg), anatomy, and clinical judgment. Site selection is based on several factors, including patient size, anatomy, presenting condition, ability to locate anatomical landmarks, clinical judgment, and experience. 15 gauge, 304 stainless steel in 15mm, 25mm and 45mm lengths. • Diamond Infant/Child Needle Selection and Insertion Technique Animation Video How and where to place an EZ IO (intraosseous line) for vascular access. The Arrow™ EZ-IO™ System supports your success by enabling fast 2 access when you encounter patients with difficult vascular access. Reuse of device creates a potential risk of serious injury and/or infection which may lead to death. • Consider longer needle to Figure 2 Figure 3 Figure 4 e non-collapsible vein. The ARROW® EZ-IO® Needle Set has a uniquely designed needle tip that drills a hole in the bone the same size as the needle, Infant/Child Needle Selection and Insertion Technique Animation Video - Review a computer generated animation of the steps to correctly select the appropriate length needle set in the infant and child, EZ-IO® Needle Set selection: Select EZ-IO® Needle Set based on patient weight (kg), anatomy, and clinical judgment. Alternative intravenous access In the event of a driver failure, disconnect the EZ-IO Power Driver, grasp the EZ-IO Needle Set Hub by hand and advance into the medullary space while twisting. Consider longer needle Loading Loading EZ-IO® Needle Sizes: 15 mm needle set – Select the 15 mm needle set for proximal and distal tibia insertion in neonates and small infants. 3 cm from the device when imaged with a spin-echo or gradient-echo pulse Reinforced 90º angle to help prevent your line from kinking. It is particularly beneficial for patients who require multiple IV sticks to Push EZ-IO Needle Set through skin until tip touches bone. ** It offers a wide choice of insertion sites 24 HOUR CLINICAL SUPPORT: 1. The EZ-IO® Needle Set is marked with black lines. Prior to drilling, with the EZ Learn about the EZ-IO system for intraosseous access. IMPORTANT: Control patient We've evolved IO access so you can choose the right tool, each time, in every emergent scenario. Reinforced 90º angle to help prevent your line from kinking. [See Selection of Appropriate Insertion Site and Needle Set, page 29 [See Pediatrics: Newborns, Infants, Children and Adolescen Needle Size Selection Clinical judgment should be used to determine appropriate needle set selection based on patient weight, anatomy, and tissue depth overlying insertion site. Discover needle sizes, driver options, anatomic sites, and more. Sterile, non-pyrogenic, in The Arrow ™ EZ-IO ™ System provides a versatile solution that is appropriate for virtually all patient types, regardless of underlying cause of vein inaccessibility. Whether you prefer manual or powered ARROW EZ-IO Intraosseous Vascular Access System Which of the statements concerning placement of the EZ-IO Vascular Access System are correct? EZ-IOTM Needle Set selection: for 45 mm needle set should be considered for the proximal humerus site in most adults and for any site when excessive tissue overlies the insertion site. How to gain and use intraosseous access with the EZ-IO drill system. 12K subscribers Subscribed EZ-IO® NEEdlE SETS: dEScRIPTION Comprised of Catheter with Luer-lock connection, Stylet, Safety Cap. IMPORTANT: The most accurate determinant of correct needle The Arrow EZ-IO Needle Set is Sterile, Single Use: Do not reuse, reprocess or re-sterilize. Sterile, non-pyrogenic, in Is there a risk of over-penetration with the EZ-IO® Vascular Access System? Penetration of the IO needle set through the posterior cortex of the bone is a possible complication, but avoidable with Introduction This is a guide to explain explain the indications, contra-indications and and use use of the EZ-IO IO vascular vascular access access system system. Note: In the event of an EZ-IO® Power The Arrow ® EZ-IO ® Needle Set is for vascular access anytime in which vascular access is difficult to obtain in emergent, urgent or medically necessary cases for up to 24 hours. Presented by Jess Mason, MD. gauge, 304 stainless steel in 15 mm, 25 mm and Sterile, non-pyrogenic, in protective 3 The specially designed Arrow EZ-IO set and power driver enables clinician control of the insertion with proven __________ tactile feedback The patented needle tip is designed to create a hole in the bone Infant/Child Needle Selection and Insertion Technique Animation Video - Review a computer generated animation of the steps to correctly select the appropriate length needle set in the infant and child, Note: If EZ-IO® Power Driver stalls and EZ-IO® Needle Set will not penetrate the bone, operator may be applying too much downward pressure to penetrate bone. Color-coded needle system enables quick selection and post-insertion EZ-IO® NEEDLE SETS: DESCRIPTION Comprised of Catheter with Luer-lock connection, Stylet, Safety Cap. 25 mm needle set – Select the 25 mm needle set for distal This video demonstrates the placement of an intraosseous needle in adult patients. The Arrow EZ-IO Needle Set is Sterile, Single Use: Do not resuse, reprocess or re-sterilize. Push needle set tip through skin until tip rests against bone. Prior to drilling, with the Infant/Child Needle Selection and Insertion Technique Animation Video Recommend for use with all EZ-IO™ Needle Set insertions. Sterile, non-pyrogenic, in Needle Size Selection Clinical judgment should be used to determine appropriate needle set selection based on patient weight, anatomy, and tissue depth overlying insertion site. The EZ-IO® Vascular Access System uses the intraosseous space of EZ-IO Needle Sets Manufacturer: TELEFLEX MEDICAL View Full Image Arrow ™ EZ-IO ™ Manual Needle Set The Arrow ™ EZ-IO ™ Manual Needle Set is designed to provide controlled vascular access via the intraosseous (IO) route to How to gain and use intraosseous access with the EZ-IO drill system. In the event of a EZ-IO® NEEdlE SETS: dEScRIPTION Comprised of Catheter with Luer-lock connection, Stylet, Safety Cap. 15 gauge, 304 stainless steel in 15 mm, 25 mm and 45 mm lengths. Kits Site Identification & Selection Intraosseous (IO) site selection depends on patient age, size, anatomy, presenting condition; as well as ability to locate anatomical landmarks, and clinical judgment and EZ-IO® NEEdlE SETS: dEScRIPTION Comprised of Catheter with Luer-lock connection, Stylet, Safety Cap. 5 mm of the Cannula (at least one black line) must be visible outside the skin. Color-coded needle system enables quick Arrow® EZ-IO® Infant Child Needle Selection and Insertion Technique Animation Video How to Perform Intraosseous IO Insertion Step by Step Guide for Paramedics & Emergency Clinicians Immediate Vascular Access To The Central Circulation Within Seconds EZ-IO® provides the medical professional immediate vascular access to the central circulation within seconds, delivering The 45mm LD Needle Set provides the length to effectively gain access to the intraosseous space on most patients and is ideal for the humerus site. Needle selection should be based on patient weight, anatomy and tissue depth overlying the insertion site. Reuse of device creates a potential risk of serious injury and/or infection that may lead to death. Consider longer needle Attach EZ-IO® Needle Set to EZ-IO® Power Driver and remove Safety Cap from Cannula. IMPORTANT: Control patient Intraosseous (IO) access can be obtained using manual or drill-inserted devices for insertion of specialised needles; IO access uses the medullary space as a non collapsible entry point into the rrow® EZ-IO® Clinician for safe and proper use of the EZ-IO® Device. Reuse of device creates a potential risk of serious injury and/or EZ-IO® NEEDlE SETS: DEScRIPTION Comprised of Catheter with Luer-lock connection, Stylet, Safety Cap. Sterile, non-pyrogenic, in Arrow ® EZ-IO ® Needle Set - 45 mm The Arrow ® EZ-IO ® Needle Set is for vascular access anytime in which vascular access is difficult to obtain in Clinical Education Resources Resources and Literature At Teleflex, we're dedicated to practical innovation in Intraosseous Access. Introduction This is a guide to explain explain the indications, contra-indications and and use use of the EZ-IO IO vascular vascular access access system system. The Arrow EZ-IO Needle Set is Sterile, Single Use: Do not reuse, reprocess or re-sterilize. In the event of a This page includes the following topics and synonyms: Intraosseous Access, Intraosseous Infusion, Intraosseous Cannulation, Intraosseous Line, IO Line, IO Recommend for use with all EZ-IO™ Needle Set insertions. PAEDIATRICS: Learn the difference between pink, blue, and yellow intraosseous needles. The Arrow EZ-IO Needle Set has a uniquely designed needle tip that drills a hole in the bone the same size as the needle, minimizing risk of inf ltration/extravasation Removal Removal of the intraosseous needle must be ordered by the medical team. Below are some helpful EZ-IO Guidelines for use, insertion and removal Indications System used to gain intraosseous access in adult and paediatric patients in a clinical emergency or when vascular access is difficult but needed SET SELECTION Select EZ-IO® Needle Set based on patient weight, anatomy, and clinical judgment. Replace the EZ-IO Power Driver when the LED begins blinking red. We would like to show you a description here but the site won’t allow us. The Arrow™ EZ EZ-IO needle size comparison at a tibial bone site. Infant/Child Needle Selection and Insertion Technique Animation Video - Review a computer generated animation of the steps to correctly select the appropriate length needle set in the infant and child, In non-clinical testing, the image artifact caused by Teleflex’s Arrow® EZ-IO® Needle Set, extends approximately 6. 800. The most modern drill based device, the EZ-IO (Teleflex, Wayne, PA, USA), consists of a small, battery-powered device, and three 15G needles that vary in length according to weight EZ-IO® is an immediate vascular access option that provides peripheral venous access with central venous catheter performance. Prior to insertion, with the EZ- IO® Arrow® EZ-IO® uses the intraosseous space of the humerus, tibia, and distal femur (pediatrics) as a large, non-collapsible vein.
© Copyright 2026 St Mary's University